Modified 11/03/04
IntroductionThis circuit is a lamp control system for use in a photographic darkroom. Two relays control the safelamp and enlarger lamp. Exposure measurement and timing functions are included. Features
Specifications
OperationThere are four screens that may be displayed.
MAIN screen
This is the main screen. Control always returns to this screen.
Pressing SAF toggles the safelight on and off.
Pressing FOC turns the enlarger lamp on for focusing
and displays the EXPOSURE METER screen.
Pressing EXP displays the EXPOSURE TIMER screen.
Pressing TIMR displays the GENERAL TIMER screen.
Click on photo to display full size image. The four push button switches are located directly below the display, aligned with the menu prompts. EXPOSURE METER screen
This screen turns the enlarger on and displays the output of the photocell that
is placed under the
image displayed on the enlarger easel. It allows the user to set the enlarger
lens aperature for consistent gray density. Results are displayed as 0% to 200%
with 100% being the target exposure. Photocell gain is adjustable. When
the ADC reads 2.5V (50% of the maximum 5V input) the display shows 100%.
Since the energy radiating from the red or yellow safelight significantly
affects the photocell reading, the safelight is automatically shut off two seconds
after coming into this screen, and is turned back on when leaving this screen.
Pressing RET returns to the main screen.
![]() Regardless of whether you chose to meter highlight areas, gray areas, or dark areas, this exposure meter is is simply a method to achieve the same illumination intensity from print to print, negative to negative. The intensity is controlled by the enlarger lens aperature. A series of test strips will determine the actual exposure time and development time required; thereafter you use this metering facility to set only the aperature and maintain that same exposure/development time. EXPOSURE TIMER screen
This screen allows the user to set the enlarger exposure time from 1 to 99 seconds. Pressing DEC decrements the set time. Pressing INC increments the set time. Pressing BEG begins the exposure by turning on the enlarger lamp for the set time. Pressing RET returns to the MAIN screen.
This screen is displayed during the exposure time period. The time is decremented every second. When the exposure time is done or if the RET button is pressed and held, the enlarger lamp is turned off and the MAIN screen is again displayed. GENERAL TIMER screen
This screen allows the user to set and start the general timer. One use is for timing film developing. The timer will count up from 00:00 up to 59:59 (min:sec). An alarm time may be set. Pressing DEC decrements the alarm time by ten seconds. Pressing INC increments the alarm time by ten seconds. Pressing BEG begins/starts the timer. Pressing RET returns to the main screen.
This screen is displayed while the general timer is running. If the alarm time was set to 00:00, the alarm is disabled. If set to anything else, the alarm will beep every second once that time period has elapsed, and the timer will continue to run. Pressing and holding the SIL button will silence the alarm. If the timer reaches 59:59 or if the RET button is pressed and held, the timer is stopped and the MAIN screen is again displayed. SETUP SCREEN
This screen allows the user to set the paper speed that will be factored into the exposure measurement. This ranges from 50 to 950, and increments by 50. Pressing DEC decrements the speed by 50. Pressing INC increments the speed by 50. Pressing RET returns to the main screen. Technical ReferenceHARDWARE
SOFTWARE
CORRECTIONS / UPDATES
|